Closed floor bearing plate yxb65-170-510

Release time:2021-09-02 16:25 Browse times:2155second

Section properties of composite floor bearing plate
Plate thickness t (mm) Unit weight m (kg / ㎡) Section moment of inertia I (CM4 / M) Section resistance moment w (CM) ³/ m)
0.8 12.31 98.60 22.41
0.9 13.85 110.93 25.21
1.0 15.39 123.25 28.01
1.2 18.47 147.90 33.61

Calculation parameters of concrete composite floor bearing plate
Combined plate thickness (mm) Steel plate thickness (mm) Self weight of composite plate (kg / m2) Allowable unsupported span at construction stage (mm)
Single span Double span Three span
120 0.75 3.051 2600 3200 3260
0.8 3.059 2650 3280 3360
0.9 3.073 2750 3400 3580
1.0 3.091 2850 3520 3750
1.2 3.121 3000 3700 3950
130 0.75 3.296 2550 3150 3190
0.8 3.304 2630 3160 3300
0.9 3.318 2730 3350 3480
1.0 3.333 2800 3500 3680
1.2 3.363 3000 3660 3900
140 0.75 3.541 2500 3050 3100
0.8 3.549 2580 3180 3210
0.9 3.563 2700 3300 3400
1.0 3.578 2750 3400 3590
1.2 3.608 2850 3600 3850